The dimensions that decide a usable archive room: wall runs, aisle width for full drawer extension, ceiling clearance and where the drying zone belongs.

Selection Guides | 2026-09-08 | Luoyang Guanting Office Furniture Co., Ltd.

Archive rooms fail in predictable ways: a cabinet run that cannot open its drawers because the aisle is 450 mm wide, a top section that blocks a sprinkler head, or a drying cabinet placed in the archive so wet slides travel across the department. All three are decided at layout stage.

Measure four things before drawing anything

MeasurementWhy it decides
Continuous wall runHow many groups fit; deduct columns, fire boxes and sockets
Ceiling clearance to the lowest obstructionHow many sections can stack; sprinkler and duct clearance
Aisle widthWhether drawers can fully extend with a person behind them
Door opening and corridor widthWhether sections arrive assembled or flat-packed

Aisle width: the number people get wrong

A 480 mm deep drawer needs roughly 530 mm to open, and a person standing at it needs about 600 mm more. In practice:

  • Single-sided run: 1.0–1.2 m aisle is comfortable.
  • Two runs facing each other: 1.4–1.6 m between cabinet fronts, otherwise two people cannot work at once.
  • Mobile shelving: the open aisle must still meet the single-sided figure.

If the room only offers 800 mm, the answer is not a shallower cabinet but a narrower section width, because drawer depth is fixed by the cassette length.

Wall runs and zoning

Plan the room in zones rather than in cabinets:

  1. Block archive on an inner wall, away from daylight and away from the door where dust enters.
  2. Slide archive on the longest run, with a clear aisle in front — this is the zone opened most often.
  3. Drying beside the staining bench, outside the archive room.
  4. Board storage at bench height or under it.

Numbering should follow the zones: A for blocks, B for slides, then group number, drawer number, position. That way a request for “B-04-12” tells a colleague which end of the room to walk to before they open anything.

Ceiling and services

Cabinet height is limited by the lowest obstruction, not by the room height. Sprinkler heads typically need 450 mm clearance below them, and light fittings and ducts are often lower than the ceiling. A four-section group at 1.56 m is comfortable in a 2.4 m room; a stack reaching 2.0 m in the same room may need relocation of a light fitting.

A layout you can hand to a supplier

A sketch with four numbers — wall run, aisle width, ceiling clearance and door opening — plus the annual block and slide volumes is enough to produce a section plan. Suppliers who ask for more than that are usually about to propose a custom size, which is fine, but should say so.

See combined archive solutions for how the four cabinet families share a wall, and the case studies for installed examples.

Need a cabinet for a specific room? Call +86 139 3881 2326 or send the dimensions — we will return a section and drawer plan.